40
MT2834ZPX Owner's Manual
S-Registers
Certain Command Mode configurations are stored in memory registers
called, S-Registers. The
S
command is used to assign a value to, and
to read the current value of an S-Register. To assign a value to an S-
Register, enter the letter
S
,
followed by the S-Register number and an
equals sign (
=
)
.
To read an S-Register value, enter the letter
S
followed by the S-Register number and a question mark (
?
), then hit
RETURN. To verify that the S-Register value was entered correctly,
enter for example,
ATS8?
and hit RETURN. You should receive a
response of the assigned value given to that S-Register.
S0
Number of Rings Until Modem Answers
Unit: 1 ring
Range: 0-255
Default: 0
Description: Sets the number of rings before the modem answers.
S1
Rings Which Have Occurred
Unit: 1 ring
Range: 0-255
Default: 0
Description: Counts the number of rings that have occurred.
S2
Escape Code Character
Unit: ASCII Character
Range: 0-127
Default: 43 (
+ sign
)
Description: Defines the escape code character.