ModemModule
Model MT3334SMI Evaluation Kit
Data/Fax Socketed Modem
Developers Guide
Przeglądanie stron 0
1 2 3 4 5 6 ... 73 74

Podsumowanie treści

Strona 1 - Developer’s Guide

ModemModuleModel MT3334SMI Evaluation KitData/Fax Socketed ModemDeveloper’s Guide

Strona 2 - Trademarks

ModemModule Developer’s GuideMT3334SMI10Test/Demo Board SpecificationsThe ModemModule Test/Demo Board kit includes a modem module, a power transformer

Strona 3 - Contents

Chapter 1 - Introduction and DescriptionMT3334SMI 11Test/Demo Board Block DiagramSpeaker DS1SocketModemPowerSupplyPowerSwitchPowerConnectorRJ-11Conne

Strona 4 - Appendixes

ModemModule Developer’s GuideMT3334SMI12MT3334SMI Pin-outThe MT3334SMI uses a 20-pin interface to provide an on-board DAA with tip and ring connection

Strona 5

Chapter 1 - Introduction and DescriptionMT3334SMI 13Typical ApplicationThe table below shows the MT3334SMI pinouts and Figure 1-6 illustrates a typica

Strona 6 - Features

ModemModule Developer’s GuideMT3334SMI14MT3334SMI Design ConsiderationsThis section discusses hardware considerations, PC board layout considerations,

Strona 7 - Technical Specifications

Chapter 1 - Introduction and DescriptionMT3334SMI 15Safety: All creepages and clearances for the MT3334SMI have been designed to meet requirementsof

Strona 8 - MT3334SMI8

ModemModule Developer’s GuideMT3334SMI16MT3334SMI PlacementFigure 1-8 illustrates where to place the MT3334SMI on a typical Motherboard. It must be pl

Strona 9 - Physical Dimensions

Chapter 1 - Introduction and DescriptionMT3334SMI 17Telecom Labeling RequirementsFCC regulations require labeling of registered Telephone and Data Ter

Strona 10

ModemModule Developer’s GuideMT3334SMI18Reregistration(From Form 730 Application Guide Appendix C-2) http://www.fcc.gov/formpage.htmlPrivate label d

Strona 11 - Test/Demo Board Block Diagram

Chapter 2 - AT Commands, S-Registers,and Result Codes

Strona 12 - MT3334SMI Pin-out

Developer’s Guide88312201 Revision BModemModule (Model MT3334SMI)This publication may not be reproduced, in whole or in part, without prior expressed

Strona 13 - Typical Application

ModemModule Developer’s GuideMT3334SMI20IntroductionThe AT commands are used to control the operation of your modem. They are called AT commandsbecaus

Strona 14 - Loaded 4 Pin Modjack

Chapter 2 - AT Commands, S-Registers, and Result CodesMT3334SMI 21Command: Bn Communication Standard SettingValues: n = 0–3, 15, 16Default: 1 and 16De

Strona 15

ModemModule Developer’s GuideMT3334SMI22Command: In Information RequestValues: n = 0–5, 9, 11Default: NoneDescription: I0 Display default speed and co

Strona 16

Chapter 2 - AT Commands, S-Registers, and Result CodesMT3334SMI 23Command: Sr? Read Register ValueValues: r = S-register numberDefault: NoneDescriptio

Strona 17 - FCC Part 68

ModemModule Developer’s GuideMT3334SMI24Command: &Fn Load Factory SettingsValues: n = 0Default: NoneDescription: &F0 Load factory settings as

Strona 18 - Reregistration

Chapter 2 - AT Commands, S-Registers, and Result CodesMT3334SMI 25Command: &Zy=x Store Dialing CommandValues: y = 0–3 (callback security disable

Strona 19

ModemModule Developer’s GuideMT3334SMI26Command: \Nn Error Correction Mode SelectionValues: n = 0–5, or 7Default: 3Description: \N0 Non-error correcti

Strona 20 - Introduction

Chapter 2 - AT Commands, S-Registers, and Result CodesMT3334SMI 27Command: %DCn AT Command ControlValues: n = 0 or 1Default: 0Description: %DC0 T

Strona 21 - MT3334SMI 21

ModemModule Developer’s GuideMT3334SMI28S-RegistersCertain modem values, or parameters, are stored in memory locations called S-registers. Use the Sco

Strona 22 - MT3334SMI22

Chapter 2 - AT Commands, S-Registers, and Result CodesMT3334SMI 29S43 decimal 0–1 1 For testing and debugging only. Enables/disables V.32bis start-up

Strona 23 - MT3334SMI 23

iiiContentsChapter 1 - Introduction and DescriptionIntroduction ...

Strona 24 - MT3334SMI24

ModemModule Developer’s GuideMT3334SMI30Result CodesIn command mode your modem can send responses called result codes to your computer. Resultcodes ar

Strona 25 - MT3334SMI 25

Chapter 3 - Class 1 Fax Commands

Strona 26 - MT3334SMI26

ModemModule Developer’s GuideMT3334SMI32IntroductionThe Service Class 1 standard (EIA/TIA-578) defines the commands that a PC user may issue toconfigu

Strona 27 - MT3334SMI 27

Chapter 3 - Class 1 Fax CommandsMT3334SMI 33Table 3-1. Fax MOD (Modulation) Parameter ValuesValue Modulation Speed (bps) Requirements3 V.21 ch.2 300

Strona 28 - S-Registers

ModemModule Developer’s GuideMT3334SMI34Command: +FCLASS=<value> <Enter>Function: Select Service ClassValues: 0, 1, 2Default: 0 (data mod

Strona 29 - MT3334SMI 29

Chapter 3 - Class 1 Fax CommandsMT3334SMI 35Command: +FRS=? <Enter>Function: Display the range of stop-transmission-and-wait period valuesValue

Strona 30 - Result Codes

ModemModule Developer’s GuideMT3334SMI36Command: +FRM=? <Enter>Function: Display the valid range of receive data modulation valuesValues: <

Strona 31

Chapter 3 - Class 1 Fax CommandsMT3334SMI 37Flow ControlXON/XOFF flow control is used by the ModemModule to match the PC-to-modem data rate to theline

Strona 32

ModemModule Developer’s GuideMT3334SMI38Table 3-2. Single-Page Class 1 Transmit ExampleAction by Action byCommand Respone Local Modem Remote PCAT+FCL

Strona 33

Chapter 3 - Class 1 Fax CommandsMT3334SMI 39Table 3-3. Single-Page Class 1 Answer & Receive ExampleAction by Action byCommand Respone Local Modem

Strona 34

ivAppendixesAppendix A - Regulatory Agency Compliance ...

Strona 35

ModemModule Developer’s GuideMT3334SMI40

Strona 36

Chapter 4 - Class 2 Fax Commands

Strona 37 - Sample Sessions

ModemModule Developer’s GuideMT3334SMI42IntroductionThis chapter provides fax software developers with specific Class 2 fax command protocolinformatio

Strona 38 - Action by Action by

Chapter 4 - Class 2 Fax CommandsMT3334SMI 4350 - 69 Transmit phase D hang-up codes52: No response to MPS repeated 3 times53: Invalid response to MPS

Strona 39 - MT3334SMI 39

ModemModule Developer’s GuideMT3334SMI44+FDCC Fax Capability ParametersCommand syntax: +FDCC=VR,RB,WD,LN,DF,EC,BF,STResponse syntax: VR,BR,WD,LN,DF,EC

Strona 40 - MT3334SMI40

Chapter 4 - Class 2 Fax CommandsMT3334SMI 454: 12000 bits/s V.33 or V.175: 14400 bits/s V.33 or V.17WD: Page width0: 1728 pixels in 215 mmLN: Page len

Strona 41

ModemModule Developer’s GuideMT3334SMI46DF: Data compression format.0: 1-D modified HuffmanEC: Error correction.0: Disable ECMBF: Binary file transfer

Strona 42

Chapter 4 - Class 2 Fax CommandsMT3334SMI 47+FK Session TerminationCommand syntax: +FKThis command causes the modem to terminate the session in an ord

Strona 43 - +FCTCRTY ECM Retry Count

ModemModule Developer’s GuideMT3334SMI48+FPTS Page Transfer StatusCommand syntax: +FPTS=<ppr>1: MCF Page good2: RTN Page good; retrain requested

Strona 44 - +FDCS Current Session Results

Chapter 4 - Class 2 Fax CommandsMT3334SMI 49+FDIS Reports DIS Frame InformationSyntax: +FDIS:VR,BR,WD,LN,DF,EC,BF,STUsage: Reports remote FAX capabili

Strona 45

Chapter 1 - Introduction and Description

Strona 46

ModemModule Developer’s GuideMT3334SMI50

Strona 47

Chapter 5 - Remote Configuration

Strona 48

ModemModule User GuideMT3334SMI52IntroductionRemote configuration is a network management tool that allows you to configure modems anywherein your net

Strona 49 - +FTSI Report the Remote ID

Chapter 5 - Remote ConfigurationMT3334SMI 53Changing the Remote Escape CharacterTo increase security, you can change a remote modem’s remote configura

Strona 50 - MT3334SMI50

ModemModule User GuideMT3334SMI54

Strona 51

Chapter 6 - Troubleshooting

Strona 52 - Basic Procedure

ModemModule Developer’s GuideMT3334SMI56IntroductionEach time you turn on your modem, it performs an automatic self-test to ensure proper operation.Yo

Strona 53

Chapter 6 - TroubleshootingMT3334SMI 576. Your modem passes this test if the data received on your monitor are the same as the dataentered from your k

Strona 54 - MT3334SMI54

ModemModule Developer’s GuideMT3334SMI58Local Digital Loopback Test (V.54 Loop 2)The local digital loopback test is identical to the remote digital lo

Strona 55 - Chapter 6 - Troubleshooting

Chapter 7 - Upgrade Procedure

Strona 56

ModemModule Developer’s GuideMT3334SMI6IntroductionThe MT3334SMI socket modem provides a fully-integrated data and fax communications design forcommun

Strona 57 - Test procedure

ModemModule Developer’s GuideMT3334SMI60IntroductionYour ModemModule is controlled by semi-permanent firmware that is stored in flash memory.Firmware

Strona 58 - Test Procedure

Chapter 7 - Upgrade ProcedureMT3334SMI 61Multi-Tech BBS1. Run your favorite terminal program and dial in to the Multi-Tech BBS at 800-392-2432 (NorthA

Strona 59 - Chapter 7 - Upgrade Procedure

ModemModule Developer’s GuideMT3334SMI62Step 4: Extract the Upgrade Files1. Move the downloaded upgrade file to a temporary directory or folder on you

Strona 61 - Multi-Tech Web Site

ModemModule Developer’s GuideMT3334SMI64Appendix A - Regulatory Agency ComplianceFCC Regulations for Telephone Line Interconnection1. This equipment

Strona 62

AppendixesMT3334SMI 65Canadian Limitations Notice:NOTICE: The Industry Canada label identifies certified equipment. This certification means that the

Strona 63

ModemModule Developer’s GuideMT3334SMI66EMC, Safety and Terminal Directive ComplianceThe CE mark is affixed to this product to confirm compliance with

Strona 64

AppendixesMT3334SMI 67Appendix B - Multi-Tech Flash Programming ProtocolIntroductionThis appendix describes the protocol by which the modems are flas

Strona 65 - FCC FAX Update

ModemModule Developer’s GuideMT3334SMI68Program SequenceDTE Modem CommentsATFLP\r Request to the modem to program G Modem is ready for next program p

Strona 66

AppendixesMT3334SMI 693.3. The packets sent to the modem must be presorted by address and aligned on 128 byteboundaries (ie. each packet must start on

Strona 67 - 1. Programming the Modem

Chapter 1 - Introduction and DescriptionMT3334SMI 7Technical SpecificationsThe ModemModule meets the following specifications:Data Rates Client-to-S

Strona 68 - 3. Other programming concerns

ModemModule Developer’s GuideMT3334SMI70Extended Address RecordChar Pos Field Type Value Description1 Record Start “:”2-3 Data Byte Count “02 Always 2

Strona 69 - Data Record

MT3334SM71IndexIndexAAbort timer... 28Analog loopback test ...

Strona 70 - End of File Record

MT3334SM72ModemModule Developer’s GuideClass 1 fax commandsSample sessions ... 37Class 2 Fax commandsImple

Strona 71

MT3334SM73IndexMT3334SMIDesign Considerations... 14Features ...

Strona 72

MT3334SM74ModemModule Developer’s GuideUUpgrading the modem ... 60VV.22 mode ...

Strona 73

ModemModule Developer’s GuideMT3334SMI8Carrier Frequencies Transmit originate: 390 Hz mark ITU-T V.23 450 Hz space (1200 bps) Receive origin

Strona 74

Chapter 1 - Introduction and DescriptionMT3334SMI 9Physical DimensionsFigure 1-2 illustrates the the physical dimensions of the MT3334SMI..020 ± .0002