EnterpriseExpress Adapter/ESCON
INSTALLATION GUIDE
Installation Guide
Part Number 40-01459-D0-001
129 Middlesex Turnpike, Burlington Ma. 01803 (781) 272-8200 Fax (781) 272-0342 www.bustech.com
PCI ESCON A
dapter
Przeglądanie stron 0
1 2 3 4 5 6 ... 62 63

Podsumowanie treści

Strona 1 - PCI ESCON A

EnterpriseExpress Adapter/ESCONINSTALLATION GUIDEInstallation GuidePart Number 40-01459-D0-001129 Middlesex Turnpike, Burlington Ma. 01803 • (781) 272

Strona 3 - Table of Contents

Hardware Installation 5Chapter 2. HARDWARE INSTALLATIONInstalling the AdapterCAUTION! The PCI ESCON Adapter is a PC adapter card and as such can be da

Strona 4

6 PCI ESCON Adapter Installation Guide4. Remove the adapter from its protective anti-static bag and insert the adapter intothe chosen PCI bus slot. Ma

Strona 5 - About This Publication

Driver Installation 7Chapter 3. DRIVER INSTALLATIONThe PCI ESCON Adapter offers drivers for Microsoft's Windows 2000 Server andMicrosoft Windows

Strona 6 - What’s New in this Release?

8 PCI ESCON Adapter Installation GuideFigure 3-2. Search the FloppyThe hardware wizard will search the Windows directory and then the floppy disk.When

Strona 7 - Chapter 1. INTRODUCTION

Driver Installation 9Figure 3-4. New Found Hardware Wizard Completing

Strona 8 - Related Documentation

10 PCI ESCON Adapter Installation GuideWindows NTThe PBSA network driver is always required in order to allow Windows NT tocommunicate with the adapte

Strona 9 - Minimum System Requirements

Driver Installation 11Figure 3-6. Network Screen3. From the Select Network Adapter screen (Figure 3-7), click the Have Disk...button.Figure 3-7. Add N

Strona 10

12 PCI ESCON Adapter Installation Guide4. The Insert Disk screen is displayed (Figure 3-8).Figure 3-8. Insert Disk Dialog BoxWith the floppy inserted

Strona 11 - ARDWARE INSTALLATION

Driver Installation 13Figure 3-10. ESCON Configuration7. As shown in Figure 3-11, the adapter should now be listed in the NetworkAdapters box. Clickin

Strona 12

Federal Communications Commission (FCC) StatementWARNING: This equipment generates, uses, and can radiate radio frequency energy and if notinstalled a

Strona 14 - Figure 3-2. Search the Floppy

ESCON Configuration 15Chapter 4. ESCON CONFIGURATIONFigure 4-1. ESCON Attached ControllersOverviewESCON controllers, including the PCI ESCON Adapter (

Strona 15 - Driver Installation 9

16 PCI ESCON Adapter Installation GuideFinally, using both ESCON Directors and EMIF, it is possible for a single ESCONcontroller to communicate with m

Strona 16 - Windows NT

ESCON Configuration 17Channel Link – The address of the ESCON director port that connects to themainframe this device is to communicate with. The valu

Strona 17 - Driver Installation 11

18 PCI ESCON Adapter Installation GuideConfigurationESCON configuration may be defined and viewed from any of the upper levelsoftware including the da

Strona 18

ESCON Configuration 19In Windows NT the ESCON configuration may be accessed through the systemControl Panel. From the main screen of Control Panel dou

Strona 19 - Driver Installation 13

20 PCI ESCON Adapter Installation GuideThe Bus-Tech PCI ESCON Adapter should be included in the list.Selecting the Bus-Tech adapter and clicking Prope

Strona 20

ESCON Configuration 21device A0 and A1, enter 2. Optionally enter a Description to be associated with thisdevice.Remember that for TCP/IP Passthrough

Strona 22

TCP/IP Direct Connect 23Chapter 5. TCP/IP DIRECT CONNECTTCP/IP Direct Connect software included with the PCI ESCON Adapter provideshigh-performance, p

Strona 23 - CNTLUNIT ...,LINK=(02)

Table of Contents iTable of Contents••••••••••••••••ABOUT THIS PUBLICATION ...iiiWho Should Use This Publication...

Strona 24 - Configuration

24 PCI ESCON Adapter Installation GuideTCP/IP Direct Connect supports three link types across the ESCON channel:Channel-to-Channel (CTC), High-Speed A

Strona 25 - (See Figure 4-4)

TCP/IP Direct Connect 252. Click OK when Setup displays it’s Welcome dialog (Figure 5-4).Figure 5-4. TCP/IP Direct Connect Install Confirmation3. The

Strona 26 - Figure 4-7. Add Device Dialog

26 PCI ESCON Adapter Installation Guidedefined by the install you have just completed. Right click the connection andselect Properties (Figure 5-7).Fi

Strona 27

TCP/IP Direct Connect 277. Enter an IP address and Subnet mask to be associated with this link on the server.This is the address a mainframe-based app

Strona 28

28 PCI ESCON Adapter Installation GuideDeleting a LinkTo remove a previously installed TCP/IP Direct Connect link from Windows 2000,you must uninstall

Strona 29 - IRECT CONNECT

TCP/IP Direct Connect 29Windows NTThe following step-by-step procedure will install the TCP/IP Direct Connect andconfigure it for use without MPC+. In

Strona 30 - Windows 2000

30 PCI ESCON Adapter Installation GuideFigure 5-12. Adapter List with ESCON Adapter3. Click the Add button to add a new adapter. The Select Network Ad

Strona 31

TCP/IP Direct Connect 31Figure 5-14.Insert Disk5. Insert the TCP/IP Direct Connect diskette into your floppy. Click OK.6. The Select OEM Option dialog

Strona 32

32 PCI ESCON Adapter Installation GuideFigure 5-16. Adapter PropertiesYou must define the Link type and Link properties in order to complete theinstal

Strona 33 - Figure 5-9. TCP/IP Properties

TCP/IP Direct Connect 339. Click on Bindings. Show bindings for all adapters (Figure 5-18). Check that onlythe TCP/IP Protocol is bound to the TCP/IP

Strona 35

34 PCI ESCON Adapter Installation Guide11. Use your mouse to select TCP/IP Direct Connect from the list of Adapters boundto TCP/IP (Figure 5-20).Figur

Strona 36

TCP/IP Direct Connect 35Figure 5-21. Assigning an IP Address to the ESCON Adapter13. Click OK. Windows NT will complete the binding process and prompt

Strona 37 - Figure 5-14.Insert Disk

36 PCI ESCON Adapter Installation GuideLink ConfigurationFigure 5-22. CTC Link PropertiesFigure 5-22 shows the properties that must be configured for

Strona 38

TCP/IP Direct Connect 37MTU – Maximum Transmission Unit must match what is defined on themainframe for this connection or packet loss will occur. The

Strona 39 - Figure 5-18. Adapter Bindings

38 PCI ESCON Adapter Installation GuideMainframe ConfigurationThis section discusses configuration of the mainframe for use with TCP/IP DirectConnect

Strona 40

TCP/IP Direct Connect 39TCP/IP ProfileTCP/IP Direct Connect links require the IBM TCP/IP protocol stack running on yourSystem/390. Your TCP/IP Profile

Strona 41 - TCP/IP Direct Connect 35

40 PCI ESCON Adapter Installation GuideFigure 5-23. Multiple TCP/IP Direct Connect ESCON Configuration*** CHPID STATEMENTS ***CHPID PATH=((22)),TYPE=C

Strona 42 - Link Configuration

TCP/IP Direct Connect 41TCP/IP RoutingTCP/IP Direct Connect is a Network Driver Interface Specification (NDIS) compliantadapter driver. TCP/IP Direct

Strona 43

42 PCI ESCON Adapter Installation GuideSubnet 0 207.168.12.1 – 207.168.12.62Subnet 1 207.168.12.65 – 207.168.12.126Subnet 2 207.168.12.129 – 207.168.1

Strona 44 - Mainframe Configuration

TCP/IP Direct Connect 43Figure 5-26. TCP/IP Direct Connect Configuration ScreensNotice also that the subnet these two addresses are in is different th

Strona 45

About This Publication iiiAbout This PublicationThis User's Guide provides the information necessary to install and configure Bus-Tech's PCI

Strona 46 - IOCDS – LPAR 1

44 PCI ESCON Adapter Installation GuideUpdating Workstation ConfigurationsIn most existing networks today it will not be necessary to update the TCP/I

Strona 47 - TCP/IP Routing

TCP/IP Direct Connect 45Figure 5-28. Windows 95 TCP/IP Properties

Strona 49

Troubleshooting 47Chapter 6. TROUBLESHOOTINGIf your PCI ESCON Adapter fails to initiate successfully this chapter will provide youwith some general tr

Strona 50

48 PCI ESCON Adapter Installation GuideSTEP1. With your server powered on, check to make sure both LEDs are lit. If the topLED is Green and the bottom

Strona 51 - TCP/IP Direct Connect 45

Troubleshooting 49ESCON ConfigurationWhen the adapter loads the emulation it also loads the ESCON device configuration(see Chapter 4.). This configura

Strona 52

50 PCI ESCON Adapter Installation GuideHighlight the ESCON adapter and click Properties.Figure 6-3. ESCON Device ConfigurationThe ESCON Devices tab sh

Strona 53 - Chapter 6. TROUBLESHOOTING

Troubleshooting 51TCP/IP Direct ConnectIf TCP/IP Direct Connect is configured with a link type of HSAS or MPCPTP,please refer to the section titled “T

Strona 54

52 PCI ESCON Adapter Installation GuideFigure 6-5. TCP/IP Direct Connect Properties; CTC connectionDEVICE DEVCTC1 CTC a40LINK LINKCTC1 CTC 0 DEVCTC1;H

Strona 55 - ESCON Configuration

Help and Service Information 53Help and Service InformationIf you have questions about your new Bus-Tech product, or require technicalassistance, visi

Strona 56

iv PCI ESCON Adapter Installation GuideCHAPTER 6. TROUBLESHOOTING – This chapter takes the reader throughsome troubleshooting steps to be tried when t

Strona 57 - TCP/IP Direct Connect

54 PCI ESCON Adapter Installation GuideIf possible, be at your computer. Your technical support representative might want towalk you through the probl

Strona 58

Help and Service Information 55Customer ResponseIf you have comments or suggestions regarding our products and documentation,please send them to:BUS-T

Strona 60 - Step 3: Placing the Call

Technical specifications 57Technical SpecificationsPhysical AttributesDimensionsStandard Full Size PCI AdapterLength 12.283”Height 4.2”Power Requireme

Strona 61 - Customer Response

Introduction 1Chapter 1. INTRODUCTIONThe PCI ESCON Adapter from Bus-Tech, Inc. is a high performance adapter thatenables PCI-based systems to communic

Strona 62

2 PCI ESCON Adapter Installation GuideAdditionally, the PCI ESCON Adapter includes TCP/IP Direct Connect for theWindows 2000 and NT environments. Dire

Strona 63 - Technical Specifications

Introduction 3Minimum System RequirementsHardwareThe minimum hardware requirements for using the PCI ESCON Adapter are:- Pentium 100Mhz- 64MB RAM for